August 6, 2009 at 2:18 pm
Symptom
In the quantity structure of the application monitor, it may not be possible to choose the most recent periods if there is a large number of historical periods.
Other terms
Application monitor, ST07, RSAMON60
Solution
Implement the following corrections.
August 6, 2009 at 2:07 pm
Symptom
When you peform a System Copy with SAPinst using the Migration Monitor for the import, the following error occurs during the database build phase.
The error can be found in the fileprep_build.log:
Info: Processing of tpl file using str files
Processing undefined
ERROR: Unable to open undefined
ERROR: OS error message: No such file or directory
Other terms
SAPINST 640 Patch [...]
August 1, 2009 at 11:41 am
Symptom
The Sysplex Monitor and the respective OS07 display show incorrect values for Storage Frames Available and Storage Frames online.
Other terms
DB2 z/OS CCMS Sysplex Monitor Storage Frames
Reason and Prerequisites
The RTF Monitor displays values as float beginning with a certain size. These values are incorrectly parsed.
Solution
Import one of the following Support Packages:
SAP Basis 7.00 Support Package [...]
July 27, 2009 at 6:21 am
Symptom
In the Web browser-based version of the DBA Cockpit, you are trying to set up the WLM event monitors. Thereby, you receive one of the following SQL-errors.
DB2 V9.5:
SQL0264N Partitioning key cannot be added or dropped because table resides in a table space defined on the multi-node nodegroup “SAPEVENTMONGRP”. SQLSTATE=55037
DB2 V9.7:
SQL0612N “PARTITION_KEY” is a [...]
July 16, 2009 at 10:22 am
Symptom
Restart action is not working in SBTM_TASK_SEL
Other terms
SBTM_TASK_SEL, Task Instance Monitor, Task selection report, Restart action
Reason and Prerequisites
Task selection report retrives the Task BO action properties to decide whether the restart action is allowed or not. Task BO set the restart action properties dynamically based on the automatic task status. In case [...]
July 8, 2009 at 9:17 pm
Symptom
You can’t see message error data for Adapter Engine in CCMS even if everything is configured according to the documentation. Furthermore, the CCMS status in Runtime Workbench for Adapter Engines is always grey.
Other terms
Monitor Browser, XI, PI
Reason and Prerequisites
Due to a programming error the data provider for CCMS is not correctly registered.
Solution
In 7.10 [...]
July 3, 2009 at 5:14 am
Symptom
Some of the menu items do not work from OAM1 transaction i.e the Archivelink Monitor.
Other terms
OAM1,Archivelink Monitor
Reason and Prerequisites
This is due to the side effect of a solution given for the issue addressed in note 1289290.Note 1289290 is a prerequisite for this note.
Solution
Please implement the following code correction via SNOTE.Alternatively,please upgarde to the relevant SP.
June 26, 2009 at 11:44 pm
Symptom
The new OS07(n) needs to query the connected SAP system via RFC to find out details about the associated DB host.
Other terms
DB2, z/OS, CCMS, Sysplex Monitor, OS07, Configuration, DB host
Reason and Prerequisites
The following new function modules are delivered:
STU3_ZOS_GET_CONFIGSTU3_ADMIN_GET_SYSPLEX_NAMESolution
Import one of the following support packages: