July 23, 2009 at 12:07 am
Symptom
You have upgraded to PI 7.0 SP 18 and you notice that File Adapter messages are stuck in “TBDL”(To Be Delivered) status. Additionally, the following symptoms are noticed:
1 – File Adapter stops polling
2 – NullPointer Exceptions are seen in Audit logs
3 – Hanging file adapter locks are visible in the ‘Locking Adapter’ [...]
July 15, 2009 at 3:41 am
Symptom
An error occurred while activating BW object.
When you check the logs in RSTCO_ADMIN , you find the following error message:
“System is set to not changeable; objects cannot be changed”
Other terms
BW upgrade errors, system is set to not changeable,RSTCO_ADMIN,XPRA.
Reason and Prerequisites
Programm error.
The system is set always to “Non-changeable” during upgrade.So this error should not come [...]
July 14, 2009 at 1:50 am
Symptom
The import of deleted configuration objects fails when the imported object has a reference to an already deleted configuration object. For instance, if one performs an import of configuration object /e.g. a deleted receiver agreement which has a reference to a deleted communication channel/ the import fails with a message that the [...]
July 12, 2009 at 2:15 am
Symptom
Enterprise Services published in the Services Registry from the PI directory can not be found from a provider system configured to use the same services registry as the one where the enterprise services have been published.
Other terms
Enterprise services can not be consumed from a provider system configured to use SR
Reason and Prerequisites
The reason [...]
July 10, 2009 at 5:44 am
Symptom
XI Adapter Framework’s scheduler may fail to remove the scheduled job. When this problem occurs, the affected job may get executed continuously for some period in parallel.
This problem can be suspected when some scheduled job gets executed unexpectedly frequently while others do not get executed.
This scheduler is used by various services of the Adapter [...]
July 2, 2009 at 12:30 pm
Symptom
The line selection of the second table control within a subscreen disappears for a dialog step, or the lines are not selected for the application. The system usually displays an error message referring to lines that have not been selected.
Furthermore, when you scroll the second table control vertically within a subscreen, the session [...]
June 30, 2009 at 10:37 am
Symptom
You receive incorrect data for queries where the F-table has attributes of type DATE or TIME. You find the following entry in the trace of TREXIndexServer: “Attribute engine function not implemented (index attribute flags ) getAggregateMeasures”
Other terms
BWA, BIA, Accelerator, wrong result, date, time, not implemented
Reason and Prerequisites
Prerequisite: SAP NetWeaver [...]
June 26, 2009 at 11:39 pm
Symptom
The system component version store is not updated.
SQLException: ORA-01000: maximum open cursors exceeded
Other terms
Could not update: Error writing new entries into COMPVERS
Reason and Prerequisites
The system performs an action during which it uses the SLUtil (CVERS) library to write to the database. This generally occurs indirectly when you use the Software Delivery Manager (SDM) [...]